Water fire extinguishing system

Water or wet fire extinguishing systems are very important since water is an effective and widely used system for extinguishing fires. These systems typically include water tanks, control valves, fire pumps, sprinklers, piping, and fire alarm systems.

In the water fire extinguishing system, water is released automatically or manually to put out the fire, meaning automatic sprinkler extinguishing and manually by fire extinguishers. The use of water fire extinguishing system is very useful and vital, especially in places where there are many people or many flammable materials (such as large buildings, warehouses, factories, industries, etc.).

اطفا حریق ابی - اطفا حریق آبی - سیستم اطفا حریق آبی - سیستم اطفا حریق تر - اطفا حریق تر - انواع اسپرینگلر - اسپرینگلر مرطوب خشک - اسپرینکلر، سیستم اطفا حریق آبی

Main titles

next 00

Water fire extinguishing system components

Water fire extinguishing systems include the following equipment and tools.
– The main source or source (Storage Tank)
– Pipes and branches (Pipe Fitting)
– Main Pump
– Jokey or auxiliary pump (Jokey Pump)
– Wet Alarm Check Valve
– Gate valves
– Butterfly valves
– One-way valves (Check Valve)
– Test and drain valves
– Pressure Relief Valve
– Manometer or Pressure Gauge
– Flow switch and water flow detectors (Flow Switch)
– Sprinklers in different types (Fire Sprinkler)

اطفا حریق ابی - اطفا حریق آبی - سیستم اطفا حریق آبی - سیستم اطفا حریق تر - اطفا حریق تر - اسپرینگلر تر - انواع اسپرینگلر - اسپرینکلر، سیستم اطفا حریق آبی
next 00

What are sprinkler systems?

Sprinkler systems are designed to control or contain fires. Automatic sprinklers to control the speed of fire spread and also wet the combustible materials around the fire in advance to prevent the fire from spreading. In this case, the fire will not be extinguished until all flammable materials are extinguished or firefighters actively extinguish the fire. Suppressive sprinklers (formerly known as rapid response primary suction sprinklers (ESFR)) slow the rate of heat release from a sudden fire, thereby attempting to extinguish the fire immediately before manual intervention.

Today, most sprinkler systems are designed with an area and density approach. First, the use and materials of the building are checked to determine the level of fire risk. Generally, buildings are classified into low risk groups, general risk group 1, general risk group 2, high risk group 1 and high risk group 2. Once the hazard classification is determined, a design area and density can be arrived at using the reference tables contained in the National Fire Protection Association (NFPA) standards.   Design density is also a measure of the amount of water required per square foot of ground surface to apply to the design area.

سیستم اسپرینکلر پیش عملگر - اسپرینگلر - انواع اسپرینگلر - سیستم اسپرینگر - اسپرینکلر، سیستم اطفا حریق آبی
next 00

Application of water fire extinguishing system

This water-based system is used in areas that have electronic devices or equipment of high physical and mental value.
The preoperative system has two operators to start the operation.
In this case, if the alarm fails or gives a false alarm, the system will not work. With this fire extinguishing only if there is a real fire and there are signs such as cigarette smoke and component failure will not cause water leakage.

The pre-operator water fire extinguishing system is used in the following places:

  • Library
  • data center
  • Control room
  • All places vulnerable to water
next 00

Wet and flood sprinkler system

  • Pipe sprinkler system:

As its name suggests, in this water fire extinguishing system, there is always water in the pipes, and the pipes are connected to the city water source or the fire pump, which increases the speed of fire suppression.

This system is one of the most common sprinkler systems for fire suppression that are used by high-rise or multi-story office buildings. Among the features of this system, we can mention its cost-effectiveness and easy maintenance conditions.

  • Flood sprinkler systems:

These systems are one of the types of water fire extinguishing systems that are used in places where there is a possibility of rapid fire growth or a high risk of fire.

In this model, all water exit nozzles work together; That is, after detecting the fire, the sprinkler automatic control valve or deluge valve is opened and pressurized water is released from all the nozzles at the same time.

In this system, if there is a mistake in the fire detection section and accidental discharge of water, there is a high possibility of damaging the environment.

سیستم اسپرینکلر لوله تر - ان.اع اسپرینگلر - اسپرینکلر - اسپرینگلر تر - اسپرینکلر تر، سیستم اطفاء حریق مه آب، سیستم اطفا حریق آبی، سیستم اطفاء حریق مه آب
next 00

Blue foam fire extinguishing system

Wherever there is a possibility of liquid fire, water foam fire extinguishing system is used.

In this system, water is mixed with foam producing material; Then the produced foam is poured over the environment like a thick blanket.

With this, in addition to cooling the fire, oxygen is separated from the combustible materials.

This system is used in various places, which include:

  • Flammable liquid storage place
  • refinery
  • Airplane hangar
  • warehouse

Depending on the amount of protection required against fire, the volume and density of the production floor is different, and this water fire extinguishing system is divided into three types of low, medium and high expansion.

سیستم اطفا حریق آبی سیلابی - سیستم اطفا حریق - اطفای حریق - اطفا حریق ابی، سیستم اطفا حریق آبی
next 00

Dry pipe sprinkler systems

Among the types of sprinkler systems, dry pipe systems are the second most widely used systems. Dry pipe systems are installed in places where the ambient temperature is sometimes so cold that if the pipe is filled with water, it will freeze and prevent it from working. Common uses of dry pipe systems are in heated buildings, parking lots, open parking garages connected to heated buildings (where wet pipe systems are used), or cold storage facilities. In areas subject to NFPA regulations, the installation of ether systems is not permitted unless the temperature range Keep the environment above F40º.
In such systems, there will be no water in the piping system while the system is operating. Instead, the network is filled with air whose pressure is lower than that of the water source. In order to prevent the water in the source (which has a higher pressure) from being forced into the piping network under normal conditions, a dry valve (a special type of one-way valve) is designed to expand the contact area. It is designed in such a way that by increasing the contact surface of the valve’s tongue with the air in the piping network (compared to the higher water pressure but the smaller contact surface of the one-way valve’s tongue), more force is applied to the one-way valve’s tongue.
When one or more series of automatic sprinklers are activated, allowing air trapped in the pipe to escape from that sprinkler. When the temperature of each sprinkler exceeds the activation threshold, that sprinkler will activate independently. As the air pressure in the pipe decreases, the pressure difference in the dry pipe also changes and causes water to enter the pipe system. The flow of water required for fire control through the sprinklers is maintained until the air in the sprinklers is released. In areas covered by NFPA 13, the time between sprinkler activation and water reaching the sprinkler is limited to about 60 seconds. In industrial applications, this amount of time is called “maximum water arrival time”. The maximum arrival time ceiling is sometimes reduced depending on the hazard classification of the area protected by the sprinkler system.

سیستم اسپرینکلر لوله تر - ان.اع اسپرینگلر - اسپرینکلر - اسپرینگلر تر - اسپرینکلر تر، سیستم اطفاء حریق مه آب، سیستم اطفا حریق آبی، سیستم اطفاء حریق مه آب
next 00

Design of water fire extinguishing systems

The design of water fire extinguishing systems is based on the area covered by the system and the size of the place and the density of the space under the system. The first step is to analyze the user and content of this space. These tests determine the extent and level of fire of a building.
Based on the level of risk, buildings are divided into the following categories:
– low risk (low risk)
– Normal risk group 1
– Normal risk group 2
– High-risk group 1
– High-risk group 2
After determining the risk classification, it is necessary to determine the type of profession into three categories S1, S2 and S3. The grouping of places is directly related to the level and height of the building. According to the instructions and regulations of the firefighting organization, it specifies whether the product must be among the items listed by that organization in the list of fire extinguishing system equipment or whether it has successfully obtained national and international standards.

In the next step, the volume of water needed for the successful operation of water fire extinguishing systems should be estimated. The volume of water required also determines the dimensions of the water tank. Also, all the pressure drop and pressure increase in the extinguishing system from the tank to the sprinkler should be considered in the calculations. Today, most of these calculations are done by software and through system modeling and accurate hydraulic calculations.

next 00

Advantages of water fire extinguishing systems

In the first part, some of the advantages of water fire extinguishing systems were mentioned, which we will briefly complete in the following. – The cheapest extinguishing agent – The most available extinguishing agent – The simplicity of the extinguishing system compared to other automatic fire extinguishing systems – The system is ready to work in normal mode – Automatic fire detection – Cheaper equipment and tools than other extinguishing systems – Can be used in all kinds of spaces with different heights – The possibility of re-starting the fire extinguishing system in the shortest possible time – Can be used in different geographical areas except for very cold environments with the possibility of water freezing

In this article, we tried to examine and study safety tips against fire. You can contact our experts at Imen Datis Asia for more information to increase the safety level and choose fire alarm and extinguishing equipment.

Frequently asked questions

Water fire extinguishing systems can be installed in all types of spaces except very cold areas. In some areas, these types of systems are used even by adding antifreeze to the water in colder environments. In general, these systems can be used in the following spaces.
– Warehouses
– Shopping centers
– Parking lots
– Tall buildings
– Factories

  • Water is conductive (one of the biggest dangers of water extinguishers is the risk of electric shock).
  • Damage caused by high water pressure
  • Combination and destruction of various materials and equipment with water and huge damages caused by it
  • Fueling the fire due to the fluidity of the water

Protected elevators are used in tall buildings. These elevators help residents and firefighters during a fire. Fire alarm and smoke control systems are also installed in tall buildings.

The price of water fire extinguishing system is different depending on what type of system and what type of equipment is used. For example, the use of automatic blue fire extinguishing system is much more than manual blue fire extinguishing system. Also, extinguishing a fire through a booster pump has a higher price than installing a sprinkler.

The price of water fire extinguishing system is different depending on what type of system and what type of equipment is used. For example, the use of automatic blue fire extinguishing system is much more than manual blue fire extinguishing system. Also, extinguishing a fire through a booster pump has a higher price than installing a sprinkler.

سیستم اطفاء حریق مه آب، مه - اطفا حریق - اطفای حریق - اطفا حریق با مه - اطفا حریق آبی - سیستم اطفاء حریق - واتر میست - سیستم واترمیست، سیستم اطفا حریق آبی
Getting to know the best fire tools in Iran
سیستم اطفاء حریق مه آب، واترمیست، واتر میست - سیستم واتر میست - مه - اطفا حریق - اطفای حریق - اطفا حریق با مه - اطفا حریق آبی - سیستم اطفاء حریق، سیستم اطفا حریق آبی

Imen Datis Asia Company is recognized as one of the top companies in the private sector in the field of safety and fire fighting, relying on modern knowledge, continuous activity and the cooperation of highly specialized forces. This group is always trying to continuously and dynamically expand the safety and firefighting infrastructure of our beloved country Iran and take great steps in order to achieve goals such as the development and industrialization of new technologies.

0 0 رای ها
امتیاز
اشتراک در
اطلاع از
نام نام خانوادگی
لطفا شماره تماس خود را وارد نمایید.
لطفا ایمیل خود را وارد نمایید.
0 دیدگاه خود را با ما در میان بگذارید
بازخورد (Feedback) های اینلاین
مشاهده همه دیدگاه ها
0
لطفا دیدگاه خود را با ما درمیان بگذارید.x