imenada Imen Datis Asia Co

fire box

characteristic amount
thickness
At least 1 mm
color
An electrostatic furnace with a thickness of 80 to 100 microns
material
Do not use stainless steel grade 304L
sheet material
galvanized

Checking the fire box or fire box

Fire box or fire box is a container for keeping fire extinguishing systems, which usually contain fire hose reels and fire extinguishing capsules. After manual fire extinguishers, these equipments are among the first fire extinguishing equipments in the early moments of fire detection. Fire boxes are usually produced in red, gray or steel colors and the Latin letter F (abbreviation of the word Fire) is written on them. Firebox or fire box usually contains hose, nozzle, reel, valve and coupling and fire extinguisher, which can be different depending on the dimensions and place of use.

Fire fighting boxes are used in built-in, surface, as well as single-door, double-door, single-story, and double-story types. The contents and equipment of the fire box include: fire hose, hose reel, connecting hose or fan coil, coupling, fire extinguisher, etc.

Imen Datis Asia Technical and Engineering Company is a supplier of all kinds of fire fighting boxes in various dimensions, designs and materials.

fire box, firebox, firebox, firebox - firefighting - firefighting - safety equipment - firefighting consultant - firebox purchase - firebox price, fire alarm and extinguishing system, firefighting control panel

Application of fire box

Fire extinguishers are used to extinguish fires in residential, office, commercial buildings, factories, industrial units, etc. Imen Datis Asia’s fire boxes are very diverse in terms of color, dimensions and laser design on the box, also Imen Datis Asia produces and supplies boxes according to the customer’s taste, taking into account the standards of the firefighting organization.

1- Dry systems: this type of system is not connected to the city water pipe and its entrance is installed at the entrance of the building or the floor. Water enters the pipes by tankers and fire pumps, and its output is used in the required class. The entrance of this system is housed in a chamber outside the house or workshop building. This is the type of system where we can get the water to the closest possible point without wasting time and there is no problem when there is a fire.

2. Wet systems: This type of system is installed at the lower end of the building, that is, it is up to the top floor of the building (the roof is stretched). This type of system is connected to the city water pipe and in any case there is always water in the pipes. And water comes out of it.

Installation location of certified fire extinguisher box:

The distance between the fire boxes should be at most 30 meters so that in case of failure of each one, other fire reels can be used.

Usually, boxes are installed in corridors, corridors, footpaths and escape stairs.

  • The installation height of built-in boxes should be higher than 70 cm from the floor.
  • The installation height of the facing boxes should be above 130 cm from the floor.

Features and applications

Fire box installation location

To install the fire box, the following points should be taken into account:

  1. Installation location: The fire extinguisher box should be installed in places that are easily accessible. These places include the proximity of exits and entrances, different floors of the building, the proximity of tools and heating and electrical equipment, and areas where the risk of fire is greater. It is also important to install a fire extinguisher in places where dangerous materials may be stored.

  2. Protection of the box: The fire box should be installed in places away from sunlight and high temperature environments.

  3. Installation standard: The fire extinguisher box must be installed in such a way that any adult can easily use it and avoid serious injuries and hazards. The installation standards are:

    • Installation height: The fire extinguisher box must be installed at a height of 130 cm from the floor and in a place where it can be seen by all the residents of the floor. Suitable places for installation include hallways, front doors, corridors and emergency stairways.
    • Coverage: Each fire box can cover a radius of 20 meters.
    • Water pressure: The water pressure of each fire extinguisher box should not be less than 2 bar.
    • Distance between boxes: The distance between fire boxes should not be more than 30 meters so that in case of a problem with one box, another can be used.

These tips will help ensure effective and safe use of fire extinguishers and reduce the risk of fire.

Product benefits

المان ایمن داتیس آسیا2

Unique solutions

90 degree brass fire hydrant valve, which is connected to the body of the hoser by turning joints and installed on the hoser, to perform the task of connecting and disconnecting the incoming water to the flat fire hose.

المان ایمن داتیس آسیا1

Distinctive designs

A thick steel sheet that has been given a special shape by a press to increase its strength and resistance to change in shape and form.

ایکون

Reliable performance

It has Cross Hatch Cutter tests (paint adhesion test), Shock test (impact test), Salt spray (salt spray test according to ASTM B 117) and sheet thickness measurement test.

Related products

What features should a standard fire extinguisher have?

To ensure proper safety and performance, standard fire extinguishers must have the following features:

  1. Materials and resistance: The box must be made of quality and resistant materials to be strong against shocks and heat and prevent deformation.

  2. Appropriate capacity: These boxes should be suitable for dealing with small and medium fires and have sufficient capacity to store fire extinguisher powder and related equipment.

  3. Markers and signs: The box should be marked with markers and signs so that it can be easily identified and accessed in case of an accident.

  4. Locks and safety handles: The box should be equipped with locks or safety handles to prevent unauthorized persons from accessing the internal equipment.

  5. Manual: Each box must have a manual that includes instructions and training for the proper use of internal equipment.

  6. Standards and approvals: The boxes must comply with national and international safety and quality standards and approvals to ensure their effective operation.

Choosing a standard and quality fire extinguisher, as a vital tool in dealing with fires, is very important and has a direct impact on your safety performance.

Technical specifications of the fire box

characteristic amount
material
fiberglass, steel, get steel
color
An electrostatic furnace with a thickness of 80 to 100 microns
characteristic amount
material
fiberglass, steel, get steel
color
An electrostatic furnace with a thickness of 80 to 100 microns
Door and body thickness
At least 1 mm
characteristic amount
Door and body thickness
At least 1 mm

Ayman Datis Asia Technical and Engineering Company, as a company approved by the fire department, in addition to consulting in order to obtain fire department approval, is an importer and supplier of all types of fire department equipment, including fire pumps, fire valves, fire alarm and fire extinguishing equipment from the best and It is the most reliable domestic and foreign brands. In this regard, Ayman Datis Asia Technical and Engineering Company has the official representative of Suffex fire fire valves and lobby fire pumps in Iran.

For more information and price inquiries, please contact our experts.

To receive free consultation and price inquiry, please contact Imen Datis Asia experts at 021-44096110 or 021-44036839.

Download documents

PDF file

fire box

0
لطفا دیدگاه خود را با ما درمیان بگذارید.x