imenada Imen Datis Asia Co

fire booster pumps

characteristic amount
debi
50 GPM up to 3000 GPM
Head
(PSI) 87 to 290
Voltage
220VAC+380VAC+415VAC
Engine type
Diesel + Electric

Checking the fire booster pumps

Fire booster pumps are a set of fire pumps that are assembled on a structure based on the NFPA20 standard. The main task of booster pumps is to increase the water pressure to the desired level for fire fighting systems to extinguish the fire.

The general structure of booster pumps can be divided into the following categories:

(Diesel+ Jockey + Electric)

(Electric + Jockey)

(Diesel + Jockey)

Imen Datis Asia Technical and Engineering Company is a supplier of all types of fire pumps, including diesel pumps, jockey pumps, electric pumps, etc., as well as the designer and implementer of fire alarm and fire pump booster projects.

The construction of these booster pumps is done according to the environmental conditions as well as the desired pressure and flow rate and the type of use using Horizontal split case fire pumps or END SUCTION series pumps.

بوستر پمپ آتش نشانی، پمپ آتش نشانی، اتش نشانی، اتشنشانی، آتشنشانی، آبرسانی، تبرسانی، پمپ صنعتی، بوستر پمپ، بوستر پمپ قیمت، قیمت بوستر ، خرید بوستر پمپ

Fire Pump Boosters include parts such as the chassis of the pumps, inlet and outlet valves, inlet and outlet collectors, control panel or control board, inlet and outlet manometers and control equipment. 

Installation, commissioning and use of booster pumps in industries and all types of residential, office, commercial, etc. buildings will cause the fire extinguishing system (foam, water) to perform fire extinguishing operations in the best possible way in the desired location. .

One of the most important points of view regarding the design and construction of booster pumps is the correct response in emergency situations and performing the operation in question with high speed and accuracy automatically and manually. We at Imen Datis Asia Company are proud to help you by providing house pump plans in the shortest possible time by complying with the existing standards and regulations to supply various booster pump components with the best quality and reasonable price in carrying out various projects.

Features and applications

In the video below, we have reviewed the fire pump booster and its components, as well as how it works.

Benefits of fire pump booster

المان ایمن داتیس آسیا2

Unique solutions

Reliable and high-performance engine power for quick water delivery to accident areas

المان ایمن داتیس آسیا1

Distinctive designs

Using two types of engines (diesel and electric)

ایکون

Reliable performance

Design resistant to harsh environmental conditions, including heat and pressure

As we said, Fire Pump Boosters are equipment used in firefighting systems to increase water pressure and perform fire extinguishing operations. These pumps are used to increase the water pressure in the fire network for fire extinguishing so that water can be used effectively against the fire.

Booster fire pumps are usually used as part of fire fighting systems. When the water pressure from the main device is not enough, booster pumps can supply water to the fire fighting system by increasing the water pressure to the desired level.

Booster fire pumps usually consist of an engine and a pump that move water from one point to another. These pumps usually operate using electricity, but in some cases, mechanical systems such as diesel engines are also used, known as diesel fire pumps.

By using the fire pump booster, the water pressure in the fire system increases, and in this way water can be transported to longer distances and places where the water pressure is not enough. This can be very useful and vital in emergency situations, such as fire incidents, so that the fire can be dealt with quickly and effectively.

Imen Datis Asia Technical and Engineering Company, as a company approved by the fire department, in addition to consulting in order to obtain fire department approval, is an importer and supplier of all types of fire department equipment, including fire pumps, fire valves, fire alarm and fire extinguishing equipment from the best and It is the most reliable domestic and foreign brands. In this regard, Imen Datis Asia Technical and Engineering Company has the official representative of Safex fire fire valves and lubi fire pumps in Iran.

For more information and price inquiries, please contact our experts.

Technical specifications of fire pump booster

characteristic amount
nominal size
200 and 150 and 100 and 80 NB
Dimensions
3 to 8 inches
characteristic amount
nominal size
200 and 150 and 100 and 80 NB
Dimensions
3 to 8 inches
Installation type
vertical
trim
Galvanized connection with brass valve
characteristic amount
Installation type
vertical
trim
Galvanized connection with brass valve

Technical features of the fire pump

Fire pumps must be able to have a very strong and effective performance and safety in order to pump water or extinguishing materials such as foam to the areas that are on fire, so fire pumps have important characteristics that should be taken into account when choosing.

Among these specifications, we can mention things such as capacity, pressure, flow rate, input and output flow, type of pump and motor, power source, international standards and certificates, etc.

Engine type: Fire pumps are generally diesel or electric.

Inlet and outlet flow: This parameter indicates the size of the inlet and outlet connections and piping of the pump.

Pump pressure: It indicates the pressure with which the pump can pump water or extinguishing materials. It is a unit of pressure (PSI) or load.

Pump capacity: This parameter shows the amount of water or extinguishing materials that the pump can pump in a certain period of time.

Type of pump: There are different types of fire pumps, including centrifugal pumps, piston pumps, etc.

Standards and certification: fire pumps must comply with certain standards and must have certificates related to safety standards.

According to the features mentioned about fire pumps, the price of fire pumps may vary depending on their type and use. Dear ones, you can contact our experts and specialists at Ayman Datis Asia Technical and Engineering Company to inquire about the price and also to get technical advice and choose the best fire pumps for your projects.

How does the fire pump booster work?

The fire pump booster, by maintaining the water pressure at a predetermined value, compensates this pressure drop in the event of a pressure drop in the system, which is sensed by the sensors installed on the pump booster. Information about this event is transmitted to the switchboard. If a jockey pump is also present, it enters the circuit first and corrects the pressure drop.

If the required flow rate is greater than the ability of the jockey pump and a greater pressure drop occurs in the circuit, the control panel will issue an order to run the main pump. The main pump is automatically turned on to increase the pressure of the system with the help of the jockey pump. The main booster pump of the fire pump remains in the active circuit as long as the fire extinguishing system needs water, and whenever the pressure switch detects the pressure value, the corresponding signal is sent to the electrical panel.

The control panel also issues the command to start the electric motor/diesel pump motor. If the main pump cannot be turned on for any reason, the reserve pump is added to the circuit by the command of the electrical panel and plays its role as a system pressure supplier. It is important to note that the fire pump booster is not the only source of water supply for firefighting and its task is to provide the required pressure of the system.

For the fire pump booster, considering that the urban water flow rate is usually lower than the flow rate required for the fire extinguishing system, it is necessary to consider a water source or tank with a suitable flow rate for the project. The main purpose of exploitation And the use of booster pumps is to create appropriate water pressure in different parts of a complex or to provide water flow in a desirable and constant range.

Booster pump, as one of the main equipment for increasing water pressure and injecting it into water supply system or fire extinguishing system, plays a very important role in this field. The most important difference between fire booster pump and water supply pump booster is the type of pump used in each of them, which may be according to the type of pump used in these two types of booster pump, fire pump booster and water supply booster pump can be respectively fixed speed booster pump and Also called variable round.

Due to the use of a constant speed pump, the fire pump booster has a pressure switch and does not have an inverter and a pressure transmitter, but the variable speed (water supply) model has an inverter and a pressure transmitter in its electrical panel. Of course, be careful, it is not necessary to use a fixed-speed booster pump in the fire-fighting pump booster, and you can also use a variable-speed booster pump. It should be kept in mind that the fire pump booster is used for emergency situations, but the water booster should be designed in such a way that it has the ability to supply water continuously.

For each pump, two pressure switches are installed in the fire pump booster, one of the switches is a backup and standby for the other. The reason for this is that because the fire pump booster is off for a long time and only starts when there is a fire, for this reason we must have two pressure switches for each pump, so that if one of them fails, the other one enters the circuit.

A fire pump booster should consist of three components consisting of an electric pump, a diesel engine and a jockey pump, but these components are not essential in the water supply pumping system. In the fire pump booster, each pump has a separate diaphragm source on the fire line, but this is not the case in the water supply pump booster.

In booster components of fire pumps, a separate electrical panel for each pump must be installed. But this is not the case with booster pumps, and usually an electrical panel is responsible for controlling the booster pump system.

Pump booster tanks for water supply

In order to supply the required water for sprinklers and fire boxes, it is necessary to design and install tanks with a suitable capacity next to the fire pump booster. This action is done due to the high volume of water required for the fire extinguishing system, because the normal water supply systems to these places do not have the ability to supply enough water. Therefore, it is necessary to use water tanks with a suitable capacity.

What are fire pumps with UL?

UL International Accredited Laboratory is an approved organization in the United States that verifies the validity of booster pump series by performing rigorous and rigorous tests. Pumps that are UL approved are now recognized as a common and superior choice in fire extinguishing systems around the world. Most towers, commercial and residential buildings, and factories use this type of pump in their fire extinguishing system. According to the regulations of the Tehran Fire Department in Iran, high-rise buildings or buildings with a lot of infrastructure (in category S3) are required to use these pumps. Ayman Datis Asia is a supplier of all types of fire pumps with domestic and international approvals as well as after-sales services.

What buildings require a UL rated fire pump booster?

Installation of UL booster pumps is mandatory in buildings taller than 75 feet (about 23 meters). This requirement has been announced based on the NFPA 20 standard and the instructions of the Tehran Fire Department. These booster pumps are installed with the aim of increasing the pressure in the fire extinguishing piping network, and in case of weak pressure in the fire extinguishing piping network, they act as support for the main pump.

For the buildings that need approval based on the regulations of the fire department, the fire department will issue fire instructions. For this reason, these buildings must be equipped with a fire alarm and extinguishing system, and for this reason, they need to install a booster fire pump. These booster pumps act as an essential part of the fire extinguishing system. Firefighting instructions include various criteria such as fire alarm, extinguishing, architectural safety, exhaust, fire resistant door, etc.

The difference between listed and non-listed booster pumps

Listed fire pump booster is a pump that is listed as an authorized equipment by the Tehran Fire Department. The equipment, materials, or services listed in this list are subject to evaluation by the responsible legal entity. This evaluation includes testing and evaluation of materials, production of equipment and services periodically. The list indicates that equipment, materials, and services comply with approved regulations, guidelines, standards, and technical criteria and have received appropriate approval for a specific purpose from the fire department. (paragraph 1-27a- criteria for fire extinguishing systems)

According to the instructions prepared by the Tehran Fire Department, the listed equipment and materials have been tested by domestic or international accredited institutions, and the Tehran Fire Department, from organizations such as the National Standard Organization, Road, Housing and Urban Research Center, UL, Vds, FM, LPCB etc. have reviewed and approved the official technical documents to ensure their proper functioning. These products can be seen on the official website of the fire department as part of the list of fire fighting equipment.

Conclusion:

Fire pumps are not only a means of extinguishing fires, but also save human lives and valuable property in times of danger and prevent heavier damages. To select and install this equipment, you should pay attention to technical specifications and safety standards and use reliable suppliers.

Therefore, the fire pump is the main and important part of firefighting equipment and the main part of fire extinguishing systems. This vital tool performs exceptionally well in rescue missions, protecting lives, and controlling fire incidents. From now on, with a strong trust in the fire pump, fight the fire with peace of mind.

Our team is ready to accompany you on this path and give you the tools to face risks with courage and determination.

To get free consultation and price inquiry, please contact the specialists of Imen Datis Asia Company at 021-44096110 or 021-44036839.

Download documents